1, iOF
11 common contact, 12 normally closed contact, 14 normally open contact, wiring 11, 14 contact.
2. V90 holding brake
220V needs separate relay control, wiring white DC24V, black DC0V.
Connect 400V to driver X7 terminal, white B+, black B-.
3, SMC cylinder magnetic open (D-M9B)
NPN blue DC0V, brown digital quantity input point.
PNP brown DC24V, blue digital quantity input point.
SMC electrical proportional valve ITV2000 series
1 brown DC24V, 2 white analog output, 3 blue DC0V.
5, SMC pressure switch (-P is PNP — N is NPN)
NPN/PNP 1 blue DC0V, 4 black digital quantity input point, 5 brown DC24V
Analog input 1 blue DC0V, 3 white analog input point, 5 brown DC24V
6. Yadeke pressure switch DPS (P1 is PNP and N1 is NPN)
Brown DC24V, blue DC0V, black digital quantity input point
7, Mitsubishi LM-10PD tension meter
L N AC220V, left and right side tension sensor 1 green (left), 2 white (left), 5 green (right), 6 white (right), 3 red, 4 black, 7 ground wire, 9 analog input point (current), 10 analog input common end.
8. Omron proximity switch (-b is PNP — C is NPN)
Blue DC0V, black digital input point, brown DC24V
9. Omron reciprocation E3ZG-T81 (PNP)
1 brown DC24V, 3 blue DC0V, 4 black digital quantity input point (receiving end).
10. Coil diameter sensor U-GAGET30
Brown DC24V, blue DC0V, black analog input point.
11, pull rope switch (XY2-CH)
Connect 21, 22 normally closed points
12. Displacement sensor (LWH-V2)
1 DC24V, 2 analog input points, 3 DC0V
13. Keens LR-W500
Brown DC24V, blue DC0V, black digital quantity input point
14. Jens LR-TB2000
Brown DC24V, white digital quantity input point, blue DC0V
15. Water temperature/oil temperature alarm of hydraulic station
Yellow common alarm point, red high-limit alarm point, green low-limit alarm point. Yellow P/M, red digital input point.
16, hydraulic station filter
1 common point, 2 normally closed point, 3 normally open point. 1 is connected to P/M, and 3 is connected to digital quantity input point.
17, hydraulic station pressure switch
1 common point, 2 low limit alarm output, 3 high limit alarm output, connect 1, 3 contacts.
18, record the rice wheel ELCO EI40A6-H6PR-50
Brown DC24V, white DC0V, green (A) Digital quantity input point.
19. Liquid level sensor (cutting alcohol and rubbing roller)
Red DC24V, black DC0V, yellow (PNP)/ white (NPN) digital quantity input point.
20. Main engine lighting
+ DC24V, -DC0V. +/- on the label on the back of the lamp.
21, hydraulic station system, master cylinder pressure sensor (Sendx M91, 2-wire)
1, DC24V, 2, 4-20mA analog input point
22. Bending cylinder pressure sensor of hydraulic station (iFm PN2071)
1 brown DC24V, 2 white analog input, 3 blue DC0V
The day of the three-color bee alarm
1, black DC24V, 2, red failure digital output point, 3, yellow stop digital output point, 4, green operation digital output point, 5, gray buzzer digital output point, 6, yellow green ground
24. Cooling water flow switch (usually installed in hydraulic station and cooling water main pipe)
1. Brown DC24V, 2. White NC digital quantity input point, 3. Blue DC0V, 4.
5, gray COM NPN needs to be connected to DC0V, PNP needs to be connected to DC24V
25. Unwinding telephoto sensor (PC2-L)
1. Brown DC24V; 2. Black digital quantity input point; 3